What it does
This calculator covers the two most common heat questions. Conduction mode finds how fast heat flows through a slab of material, such as a window pane, a wall layer, a pan base or a metal rod, from its area, thickness and the temperature on each side. Heating mode finds how much energy it takes to raise (or how much is released by lowering) the temperature of a mass of something, like water in a kettle.
How it's calculated
Heating: Q = m × c × ΔT
In the conduction formula, Q/t is the heat flow in watts (joules per second), k is the material's thermal conductivity in W/(m·K), A is the area in m2, and d is the thickness in meters. In the heating formula, Q is heat in joules, m is mass in kg, c is the specific heat in J/(kg·°C) and ΔT is the temperature change. A temperature difference of 1 °C equals 1 K, and a difference in °F is multiplied by 5/9.
Worked examples
- A window pane: 1 m2 of glass (k = 0.84), 3 mm thick, with 20 °C on one face and 10 °C on the other. Q/t = 0.84 × 1 × 10 ÷ 0.003 = 2,800 W. See the note below on why a real window loses much less.
- Boiling water: heating 1 kg of water (c = 4,186) from 20 °C to 100 °C takes Q = 1 × 4,186 × 80 = 334,880 J, about 335 kJ or 0.093 kWh. That's roughly how much a kettle uses for a liter, before losses.
- Warming a pan: 0.5 kg of aluminum (c = 900) heated by 50 °C takes 0.5 × 900 × 50 = 22,500 J.
Thermal conductivity (k)
| Material | k (W/m·K) | Material | k (W/m·K) |
|---|---|---|---|
| Diamond | 2000 | Glass (average) | 0.84 |
| Silver | 420 | Concrete, brick | 0.84 |
| Copper | 390 | Water | 0.6 |
| Gold | 318 | Plasterboard | 0.16 |
| Aluminum | 220 | Wood | 0.08–0.16 |
| Steel, iron | 80 | Cork, glass wool | 0.042 |
| Stainless steel | 14 | Polystyrene foam | 0.035 |
| Ice | 2.2 | Air | 0.023 |
Values near 0 °C from Table 1.5 of OpenStax University Physics Volume 2. Specific heats in the heating mode are from OpenStax College Physics 2e, section 14.2 (water: 4,186 J/kg·°C at 15 °C).
Getting a realistic number
- Surfaces add resistance. The formula uses the temperatures of the two surfaces. With a window, the still air films on each side insulate far more than the glass does, so a real single-pane window between rooms at 20 °C and 10 °C loses only a small fraction of the 2,800 W figure. Use surface temperatures, not room air temperatures, to get a meaningful answer.
- Layers add up. For a wall with several layers, add each layer's thermal resistance d ÷ (kA), then divide the temperature difference by the total.
- Phase changes need extra heat. Q = mcΔT doesn't include melting or boiling. Turning water at 100 °C into steam takes far more energy than heating it there.
- k and c vary with temperature, moisture and exact composition, especially for wood, concrete and insulation.