How solar system size is calculated
A solar array has to make as much energy in a day as you use in a day. Each kilowatt of panels makes about 1 kWh for every peak sun hour, an hour of full 1,000 W/m² sunlight. That's then cut by system losses (dirt, shade, wiring, mismatch and so on) and the inverter.
System size (kW) = daily use × share to cover ÷ (peak sun hours × (1 − losses) × inverter efficiency)
Panels = system size × 1,000 ÷ panel watts, rounded up
Panel area (m²) = panel watts ÷ (1,000 W/m² × efficiency)
The 14% system loss and 96% inverter efficiency are the defaults in NREL's PVWatts model. In PVWatts, the 14% combines soiling (2%), shading (3%), mismatch (2%), wiring (2%), connections (0.5%), light-induced degradation (1.5%), nameplate rating (1%) and availability (3%).
Worked example
A home uses 900 kWh a month: 900 × 12 ÷ 365 = 29.59 kWh a day. With 4.5 peak sun hours, 14% losses and a 96% inverter, each kW makes 4.5 × 0.86 × 0.96 = 3.715 kWh a day. So the system needs 29.59 ÷ 3.715 = 7.96 kW. With 400 W panels that's 7,964 ÷ 400 = 19.9, so 20 panels (8.0 kW).
A 400 W panel at 20% efficiency is 400 ÷ (1,000 × 0.20) = 2 m². Twenty of them cover 40 m², about 431 sq ft. That's the panels alone; fire setbacks and roof edges need more roof than that.
If the bill is $150 at $0.17 per kWh, the use is 150 ÷ 0.17 = 882.4 kWh a month, which needs 7.81 kW.
Find your peak sun hours
Peak sun hours depend on where you live, the roof's tilt and direction, and the season. The free PVWatts calculator from the National Renewable Energy Laboratory (NREL) gives the figure for your address: run it for your roof, and the "Solar Radiation (kWh/m²/day)" average in its results is your peak sun hours. PVWatts also estimates the yearly output of a system size you enter, which is a good check on the answer here.
Is there still a 30% federal tax credit?
Not for new home systems. The residential clean energy credit (Internal Revenue Code section 25D) paid 30% of the cost of home solar installed from 2022 through 2025. The One Big Beautiful Bill Act (Public Law 119-21, signed July 4, 2025) ended it: the IRS says the credit isn't allowed for expenditures made after December 31, 2025, and an expenditure counts as made when the installation is complete. So a system finished in 2026 gets no 25D credit, even if you paid for it in 2025. State, local and utility incentives may still apply. Pick "Done by 2025" above only to check a system that was completed in time.
Getting a realistic number
- Use a full year of bills. Use in summer and winter can differ a lot, and the average is what matters for a grid-tied system with net metering.
- A roof that faces east or west, or is shaded, gets fewer sun hours than a sunny south-facing one. Running PVWatts for your actual roof handles this.
- Panels lose a little output each year, and adding an EV or heat pump later raises your use. Some people size up a little for that.
- This sizes the panels to your use. It doesn't size batteries, and it isn't a quote. Installers check the roof, the electrical panel and local rules.