What it does
Specific gravity (SG), also called relative density, tells you how dense something is compared with water. An SG above 1 means it sinks in water; below 1, it floats. This calculator turns a density in any common unit into SG, or an SG back into a density. You choose the water reference temperature, because water itself gets less dense as it warms. In brewing mode, it estimates alcohol by volume from your original and final gravity readings.
How it's calculated
The classic reference for liquids and solids is water at its densest, about 4 °C, as the USGS describes. The water densities used here come from the Tanaka et al. (2001) formula adopted internationally for pure water: 999.975 kg/m3 at 4 °C, 999.017 at 60 °F (15.56 °C), 998.207 at 20 °C and 997.047 at 25 °C. Against water at 4 °C, SG is almost exactly the density in g/cm3.
Worked example
Aluminum has a density of about 2,700 kg/m3. SG = 2,700 ÷ 999.975 = 2.7001, so it's 2.7 times as dense as water and sinks. Ethanol with an SG of 0.789 (against water at 4 °C) has a density of 0.789 × 999.975 = 788.98 kg/m3, so it floats on water.
Brewing: gravity, °Plato and ABV
Brewers measure the specific gravity of wort before fermentation (original gravity, OG) and after (final gravity, FG). Yeast turns sugar into alcohol, which is lighter than water, so the gravity drops. The standard homebrew estimate is:
°Plato ≈ °Brix ≈ (SG − 1) × 1000 ÷ 4 ("gravity points ÷ 4")
Example: OG 1.050, FG 1.010. ABV ≈ (1.050 − 1.010) × 131.25 = 0.040 × 131.25 = 5.25%. The OG is 50 gravity points, or about 50 ÷ 4 = 12.5 °P. Apparent attenuation is 0.040 ÷ 0.050 = 80%.
Grainfather explains that 131.25 comes from 1.05 × 100 ÷ 0.8 and that the simple formula agrees closely with more detailed ones up to an OG of about 1.050, then drifts by up to about 1.5% ABV at high gravity. Brewer's Friend notes that the points ÷ 4 rule for Plato is good to about 2% up to SG 1.060. For a quick reference, an SG of 1.040 is about 10 °P. Plato and Brix are essentially the same scale.
Getting a realistic number
- Match the reference. Two labs can quote slightly different SGs for the same liquid if one uses water at 4 °C and the other at 20 °C. The difference is about 0.18%.
- Hydrometers are calibrated at one temperature, often 60 °F or 20 °C. Reading a warm sample gives a low number unless you correct it.
- Refractometers read differently after fermentation because alcohol bends light. Don't put a refractometer FG straight into the ABV formula without a correction.