What is a board foot of spray foam?
Spray foam is sold by the board foot: 1 square foot covered 1 inch thick (144 cubic inches). A kit rated at 600 board feet covers 600 sq ft at 1 in, 300 sq ft at 2 in or 200 sq ft at 3 in. Touch 'n Seal, for example, sells FK-200 and FK-600 kits rated at 200 and 600 board feet.
With waste = board feet × (1 + waste %)
Kits = board feet with waste ÷ kit size, rounded up
R-value = thickness × R per inch
Worked example
400 sq ft of basement wall at 3 in of closed-cell foam: 400 × 3 = 1,200 board feet. With 10% for overspray and waste: 1,320 board feet ÷ 600 = 2.2, so 3 kits. At R-5.5 to R-6.5 per inch, 3 in gives about R-16.5 to R-19.5.
Open-cell vs closed-cell
| Open-cell | Closed-cell | |
|---|---|---|
| R-value per inch | about R-3.6 | R-5.5 to R-6.5 |
| 3 in gives | about R-10.8 | R-16.5 to R-19.5 |
Closed-cell foam is denser and has the higher R-value per inch; open-cell is lighter and cheaper per board foot. R-values per inch from the U.S. Department of Energy's insulation materials guide. A product's label or data sheet gives its tested R-value, which is the one to use.
Getting a realistic number
- Kit ratings are ideal yields. Cold surfaces, cold kits, overspray and uneven thickness all cut the real yield, so allow extra.
- Stud walls: subtract the studs if you're only spraying the cavities, or simply use the cavity area.
- Safety: spray foam chemicals need ventilation and protective gear while spraying; follow the kit maker's instructions and local code on covering foam with a fire barrier.